Archive: 2009 | 08 | 07 | 06 | 05

Weekly Users' Meeting Minutes -- February 18, 2009


Schedule

X-ray: No special requests.

VUV: VUV Studies on Friday - requested compressed bunch, ~200 - 250 mA

Proposed timing runs during February and March.

Feb 21: 1800 - 0230 Timing 7 bunch detuned
Feb 23: 1800 - 0230 Timing 7 bunch detuned [1800 - 2400 scheduled Timing]
Feb 27: 1800 – 0230 Timing 7 bunch compressed [1800 – 2400 Studies]
Feb 28: 1800 – 0230 Timing 7 bunch detuned
Mar 1: 1800 -0230 Timing 7 bunch detuned
Mar 2: 1800 -0230 Timing 7 bunch detuned
Mar 3: 1200 - 2400 Timing 7 bunch compressed [0800 – 2400 Studies]
Mar 4: 1200 - 2400 Timing 7 bunch compressed [0000 – 2400 Studies]

**The official weekly x-ray ring schedule is posted on NSLS TV Channel 11, which is also available on the schedules page by click on Short Range Schedules.

**The official weekly VUV ring schedule is posted on NSLS TV Channel 5, which is also available on the schedules page by click on Short Range Schedules.



Machine Status

Both rings are running well.

X13B mgu failed prefill test at this morning's fill, should be back tonight.

X25 - alarms hooked up this afternoon for cooling water, 15 minute delay before beam dump.



Storage

Clean up of storage areas underway. Contact Bob Kiss if you have any questions.


 

Subscribe to the email list for X-Ray and VUV minutes and schedules