|
|
August 6, 2003 EXAFS, X-ray Diffraction and Neutron Diffraction Study of the Heusler Alloy Co2MnSiB. Ravel1, M.P. Raphael1, V.G. Harris1, J.O. Cross2, Q. Huang3, R. Ramesh4, and V.I. Saraf4 Magnetoelectronics is an emerging field of electronics in which electron spin is used to control the properties of magnetic devices. More specifically, these devices exploit the imbalance of spin-up and spin-down conduction electrons in ferromagnetic materials. Band structure theory predicts that Heusler alloys, which are either Co2MnSi or Co2MnGe, have a complete spin imbalance in the conduction band. But the actual spin imbalance in bulk and thin film samples does not exceed 60, which might be explained by the swapping of lattice positions between cobalt and nickel atoms. We have used synchrotron and neutron techniques to confirm that extensive site-swapping occurs in Heusler alloys.
A GMR device consists of ferromagnetic layers separated by a metallic layer, as shown in Figure 1. The resistance of the device varies according to how the two ferromagnetic layers are aligned with each other. In the low resistance state, the magnetic moments of the ferromagnetic layers are in the same direction and electron transport through the sample is enhanced because a spin-up transport electron in one ferromagnetic layer is more likely to find a same-spin state to scatter into in the other ferromagnetic layer. In the high resistance state, the two ferromagnetic layers are anti-aligned and electron transport is diminished.
Currently, GMR read heads are made of ferromagnets composed of cobalt, nickel, iron, or an alloy. The read heads’ efficiency is limited by the relatively small spin imbalance of 40 percent. With 100 percent spin imbalance – as predicted by band theory – Heusler alloys would be attractive candidates for future GMR devices that would be smaller and would feature an increased surface density. In practice, Heuslers have spin imbalances of around 55%. Band theory predicts that this imbalance would be reduced if the manganese and cobalt atoms swapped their lattice positions (Figure 2), an effect also called anti-site disorder. Using neutron diffraction on bulk Co2MnSi, we found that about 15 percent of the manganese sites are occupied by cobalt. But neutron diffraction is impractical for the small sample volumes required for GMR devices. So we turned to synchrotron techniques to measure the anti-site disorder. We used a technique called extended x-ray absorption fine structure spectroscopy (EXAFS) at NSLS beamlines X23B and X23A2 on powdered and thin film samples of Co2MnSi. We found that about 15 percent of manganese sites are occupied by cobalt.
Because the photoelectron scattering amplitudes of cobalt and manganese are so similar, the anti-site disorder is measured with very poor precision by EXAFS. So we next turned to anomalous x-ray diffraction, and we were able to measure anti-site disorder in Heusler alloys in sample volumes comparable to those found in magnetoelectronic devices. By using synchrotron measurement techniques, we sccessfully characterized a dominant form of disorder that limits the application of Heusler alloys to GMR devices. BEAMLINE FUNDING PUBLICATION |